Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Braz. j. med. biol. res ; 43(12): 1160-1166, Dec. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-569007

RESUMO

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Assuntos
Animais , Masculino , Ratos , Câmaras gama/veterinária , Coração , Rim , Modelos Animais , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Ratos Wistar , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
2.
Braz. j. med. biol. res ; 42(8): 692-699, Aug. 2009. ilus
Artigo em Inglês | LILACS | ID: lil-520790

RESUMO

Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.


Assuntos
Animais , Desenho Assistido por Computador , Imageamento Tridimensional/veterinária , Modelos Biológicos , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Aumento da Imagem , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
Braz. j. med. biol. res ; 39(1): 1-7, Jan. 2006. ilus
Artigo em Inglês | LILACS | ID: lil-419153

RESUMO

The present study describes an auxiliary tool in the diagnosis of left ventricular (LV) segmental wall motion (WM) abnormalities based on color-coded echocardiographic WM images. An artificial neural network (ANN) was developed and validated for grading LV segmental WM using data from color kinesis (CK) images, a technique developed to display the timing and magnitude of global and regional WM in real time. We evaluated 21 normal subjects and 20 patients with LVWM abnormalities revealed by two-dimensional echocardiography. CK images were obtained in two sets of viewing planes. A method was developed to analyze CK images, providing quantitation of fractional area change in each of the 16 LV segments. Two experienced observers analyzed LVWM from two-dimensional images and scored them as: 1) normal, 2) mild hypokinesia, 3) moderate hypokinesia, 4) severe hypokinesia, 5) akinesia, and 6) dyskinesia. Based on expert analysis of 10 normal subjects and 10 patients, we trained a multilayer perceptron ANN using a back-propagation algorithm to provide automated grading of LVWM, and this ANN was then tested in the remaining subjects. Excellent concordance between expert and ANN analysis was shown by ROC curve analysis, with measured area under the curve of 0.975. An excellent correlation was also obtained for global LV segmental WM index by expert and ANN analysis (R² = 0.99). In conclusion, ANN showed high accuracy for automated semi-quantitative grading of WM based on CK images. This technique can be an important aid, improving diagnostic accuracy and reducing inter-observer variability in scoring segmental LVWM.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Ecocardiografia/métodos , Hipertrofia Ventricular Esquerda , Interpretação de Imagem Assistida por Computador/métodos , Redes Neurais de Computação , Disfunção Ventricular Esquerda , Estudos de Casos e Controles , Modelos Lineares , Curva ROC , Índice de Gravidade de Doença
4.
Braz. j. med. biol. res ; 33(3): 301-6, Mar. 2000. tab
Artigo em Inglês | LILACS | ID: lil-255049

RESUMO

Although iron can catalyze the production of free radicals involved in LDL lipid peroxidation, the contribution of iron overload to atherosclerosis remains controversial. The description of two mutations in the HFE gene (Cys282Tyr and His63Asp) related to hereditary hemochromatosis provides an opportunity to address the question of the association between iron overload and atherosclerosis. We investigated the prevalence of HFE mutations in 160 survivors of myocardial infarction with angiographically demonstrated severe coronary atherosclerotic disease, and in 160 age-, gender- and race-matched healthy control subjects. PCR amplification of genomic DNA followed by RsaI and BclI restriction enzyme digestion was used to determine the genotypes. The frequency of the mutant Cys282Tyr allele was identical among patients and controls (0.022; carrier frequency, 4.4 per cent), whereas the mutant His63Asp allele had a frequency of 0.143 (carrier frequency, 27.5 per cent) in controls and of 0.134 (carrier frequency, 24.5 per cent) in patients. Compound heterozygotes were found in 2 of 160 (1.2 per cent) controls and in 1 of 160 (0.6 per cent) patients. The finding of a similar prevalence of Cys282Tyr and His63Asp mutations in the HFE gene among controls and patients with coronary atherothrombotic disease, indirectly questions the possibility of an association between hereditary hemochromatosis and atherosclerosis.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doença da Artéria Coronariana/genética , Genes MHC Classe I/genética , Antígenos de Histocompatibilidade Classe I/genética , Antígenos HLA/genética , Mutação , Alelos , Frequência do Gene , Hemocromatose/genética
5.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 8(1): 170-80, jan 1998. ilus
Artigo em Português | LILACS | ID: lil-234327

RESUMO

Na cardiopatia chagásica crônica destacam-se, pela sua prevalência e importância clínica, as bradiarritmias secundárias à doença do nó sinusal, os bloqueios atrioventriculares, as extra-sístoles ventriculares e a taquicardia ventricular. O manuseio clínico dessas arritmias fundamenta-se na avaliação clínica e laboratorial do paciente, com a finalidade de caracterizar a relação com os sintomas, avaliar prognóstico do paciente e orientar a terapêutica. A conduta consensualmente aceita para o tratamento das bradiarritmias sintomáticas na cardiopatia chagásica crônica é o implante de marcapasso cardíaco artificial. No entanto, não há consenso em relação ao tratamento das arritmias ventriculares. Como princípio geral, a conduta mais defensável atualmente é a de não tratar primariamente as arritmias ventriculares assintomáticas. Deve-se tratar com métodos farmacológicos e/ou não-farmacológicos os pacientes sintomáticos (manifestaçöes pré-sincopais ou sincopais) com taquicardia ventricular não-sustentada e os pacientes que manifestam taquicardia ventricular sustentada, independentemente da tolerância hemodinâmica, bem como os sobreviventes de parada cardiorrespiratória. Os pacientes com taquicardia ventricular sustentada recorrente e função do ventrículo esquerdo presercada são candidatos à ablação cirúrgica, ou por cateter, do circuito da taquicardia. Por outro lado, nos pacientes com taquicardia ventricular sustentada mal tolerada e nos sobreviventes de parada cardiorrespiratória deve-se considerar primariamente o implante do cardioversor-desfibrilador automático, associado ou não ao uso de antiarrítmicos.


Assuntos
Humanos , Arritmias Cardíacas/prevenção & controle , Cardiomiopatia Chagásica/prevenção & controle , Morte Súbita , Prevalência , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA